DC Series
When it comes to Deep Cycle batteries, the details matter. Construction, plate chemistry, and craftsmanship all have to be in sync to get the longest life in the most demanding applications. Fullriver DC series batteries use more lead and heavier plates creating more reserve capacity and maximum life cycles.
Whether you need deep cycling power for your Boat or RV, Golf Car or Floor Cleaning machine we have the right battery for you. Fullriver Battery, “The One that Works”.
Showing 1–16 of 20 results
-
DC105-12
CA or MCA 820
CCA 680
Capacity @ 100hr Rate 115
Capacity @ 20hr Rate 105
Capacity @ 5hr Rate 86
Group Size 27
Height (inches/mm) 8.46 (215)
Length (inches/mm) 12.09 (307)
Reserve Capacity @ 25 A 175
Reserve Capacity @ 75 Amps 43
Terminal Type M8 + TP08
Voltage 12-Volt
Weight Lbs. (kg) 67 (30.4)
Width (inches/mm) 6.65 (169)
-
DC115-12
CA or MCA 910
CCA 760
Capacity @ 100hr Rate 130
Capacity @ 20hr Rate 115
Capacity @ 5hr Rate 91
Group Size 31
Height (inches/mm) 8.66 (220)
Length (inches/mm) 12.91 (328)
Reserve Capacity @ 25 A 200
Reserve Capacity @ 75 Amps 45
Terminal Type M8 + TP08
Voltage 12-Volt
Weight Lbs. (kg) 72.3 (32.8)
Width (inches/mm) 6.77 (172)
-
DC1150-2
CA or MCA 5400
CCA 4500
Capacity @ 100hr Rate 1275
Capacity @ 20hr Rate 1150
Capacity @ 5hr Rate 945
Group Size L16
Height (inches/mm) 16.18 (411)
Length (inches/mm) 11.61 (295)
Reserve Capacity @ 25 A 2235
Reserve Capacity @ 75 Amps 658
Terminal Type M10
Voltage 2-Volt
Weight Lbs. (kg) 124.8 (56.6)
Width (inches/mm) 7.05 (179)
-
DC140-12
CA or MCA 950
CCA 795
Capacity @ 100hr Rate 154
Capacity @ 20hr Rate 140
Capacity @ 5hr Rate 115
Group Size DIN
Height (inches/mm) 11.14 (283)
Length (inches/mm) 13.43 (341)
Reserve Capacity @ 25 A 260
Reserve Capacity @ 75 Amps 62
Terminal Type M8 + TP08
Voltage 12-Volt
Weight Lbs. (kg) 95.5 (43.3)
Width (inches/mm) 6.77 (172)
-
DC150-12
CA or MCA 1050
CCA 900
Capacity @ 100hr Rate 165
Capacity @ 20hr Rate 150
Capacity @ 5hr Rate 130
Group Size GC12
Height (inches/mm) 10.75 (273)
Length (inches/mm) 12.87 (327)
Reserve Capacity @ 25 A 295
Reserve Capacity @ 75 Amps 80
Terminal Type M8 + TP08
Voltage 12-Volt
Weight Lbs. (kg) 94.8 (43)
Width (inches/mm) 7.17 (182)
-
DC160-12
CA or MCA 1070
CCA 910
Capacity @ 100hr Rate 176
Capacity @ 20hr Rate 160
Capacity @ 5hr Rate 130
Height (inches/mm) 9.49 (241)
Length (inches/mm) 19.06 (484)
Reserve Capacity @ 25 A 300
Reserve Capacity @ 75 Amps 82
Terminal Type M8
Voltage 12-Volt
Weight Lbs. (kg) 102.1 (46.3)
Width (inches/mm) 6.73 (171)
-
DC180-8
CA or MCA 1200
CCA 1000
Capacity @ 100hr Rate 198
Capacity @ 20hr Rate 180
Capacity @ 5hr Rate 148
Group Size GC8
Height (inches/mm) 10.71 (272)
Length (inches/mm) 10.24 (260)
Reserve Capacity @ 25 A 335
Reserve Capacity @ 75 Amps 125
Terminal Type M8
Voltage 8-Volt
Weight Lbs. (kg) 75 (34)
Width (inches/mm) 7.17 (182)
-
DC200-8
CA or MCA 1400
CCA 1150
Capacity @ 100hr Rate 220
Capacity @ 20hr Rate 200
Capacity @ 5hr Rate 164
Group Size GC8H
Height (inches/mm) 11.77 (299)
Length (inches/mm) 10.24 (260)
Reserve Capacity @ 25 A 390
Reserve Capacity @ 75 Amps 140
Terminal Type M8
Voltage 8-Volt
Weight Lbs. (kg) 83.1 (37.7)
Width (inches/mm) 7.17 (182)
-
DC210-12-LT
CA or MCA 1425
CCA 1180
Capacity @ 100hr Rate 231
Capacity @ 20hr Rate 210
Capacity @ 5hr Rate 172
Group Size 4D
Height (inches/mm) 8.58 (218)
Length (inches/mm) 20.87 (530)
Reserve Capacity @ 25 A 400
Reserve Capacity @ 75 Amps 105
Terminal Type LT
Voltage 12-Volt
Weight Lbs. (kg) 133.4 (60.5)
Width (inches/mm) 8.23 (209)
-
DC215-12
CA or MCA 1200
CCA 1000
Capacity @ 100hr Rate 240
Capacity @ 20hr Rate 215
Capacity @ 5hr Rate 172
Group Size 921 / J185
Height (inches/mm) 14.61 (371)
Length (inches/mm) 15 (381)
Reserve Capacity @ 25 A 420
Reserve Capacity @ 75 Amps 110
Terminal Type DTW
Voltage 12-Volt
Weight Lbs. (kg) 131.8 (59.8)
Width (inches/mm) 7.01 (178)
-
DC220-6
CA or MCA 1170
CCA 990
Capacity @ 100hr Rate 242
Capacity @ 20hr Rate 220
Capacity @ 5hr Rate 180
Group Size 27
Height (inches/mm) 8.9 (226)
Length (inches/mm) 12.05 (306)
Reserve Capacity @ 25 A 425
Reserve Capacity @ 75 Amps 112
Terminal Type M8
Voltage 6-Volt
Weight Lbs. (kg) 71 (32.3)
Width (inches/mm) 6.85 (174)
-
DC224-6
CA or MCA 1080
CCA 900
Capacity @ 100hr Rate 250
Capacity @ 20hr Rate 224
Capacity @ 5hr Rate 179
Group Size GC2
Height (inches/mm) 10.63 (270)
Length (inches/mm) 10.24 (260)
Reserve Capacity @ 25 A 441
Reserve Capacity @ 75 Amps 113
Terminal Type M8 + TP08
Voltage 6-Volt
Weight Lbs. (kg) 67.9 (30.8)
Width (inches/mm) 7.09 (180)
-
DC245-6
CA or MCA 1120
CCA 930
Capacity @ 100hr Rate 270
Capacity @ 20hr Rate 245
Capacity @ 5hr Rate 198
Group Size DIN
Height (inches/mm) 10.83 (275)
Length (inches/mm) 9.61 (244)
Reserve Capacity @ 25 A 457
Reserve Capacity @ 75 Amps 120
Terminal Type AP
Voltage 6-Volt
Weight Lbs. (kg) 72.8 (33)
Width (inches/mm) 7.48 (190)
-
DC250-6
CA or MCA 1160
CCA 960
Capacity @ 100hr Rate 275
Capacity @ 20hr Rate 250
Capacity @ 5hr Rate 204
Group Size GC2 / GC2H
Height (inches/mm) 10.71 (272)
Length (inches/mm) 10.31 (262)
Reserve Capacity @ 25 A 531
Reserve Capacity @ 75 Amps 135
Terminal Type M8 + TP08
Voltage 6-Volt
Weight Lbs. (kg) 77.4 (35.1)
Width (inches/mm) 7.13 (181)
-
DC260-12-LT
CA or MCA 1830
CCA 1525
Capacity @ 100hr Rate 286
Capacity @ 20hr Rate 260
Capacity @ 5hr Rate 214
Group Size 8D
Height (inches/mm) 9.65 (245)
Length (inches/mm) 20.51 (521)
Reserve Capacity @ 25 A 578
Reserve Capacity @ 75 Amps 145
Terminal Type LT
Voltage 12-Volt
Weight Lbs. (kg) 170.6 (77.4)
Width (inches/mm) 10.59 (269)
-
DC335-6
CA or MCA 1560
CCA 1300
Capacity @ 100hr Rate 370
Capacity @ 20hr Rate 335
Capacity @ 5hr Rate 274
Group Size 902 / J305
Height (inches/mm) 14.41 (366)
Length (inches/mm) 11.61 (295)
Reserve Capacity @ 25 A 751
Reserve Capacity @ 75 Amps 184
Terminal Type DT Brass
Voltage 6-Volt
Weight Lbs. (kg) 102.7 (46.6)
Width (inches/mm) 7.01 (178)